site stats

Synthes expert nail tibia

WebAbraham Orthopaedics’ Post Abraham Orthopaedics 260 followers WebThe Expert Tibial Nail System (ETNS) is an intramedullary nailing system which covers the indications of the PTN and of the UTN/CTN, plus more distal and more proximal …

TN-Advanced Tibial Nailing System - AO Foundation

WebSales Consultant at DJD Medical, exclusive distributor of DePuy Synthes Joint Reconstruction products in Southern New England. Learn more about Matt Olsen's work … WebThe Expert TN PROtect is indicated for fractures in the tibial shaft as well as for metaphyseal and certain intra-articular fractures of the tibial head and the pilon tibiale: – 41-A2/A3 – All shaft fractures – 43-A1/A2/A3 – Combinations of these fractures For the following indications the Expert Tibial Nail should be used in combination corporate office paint colors https://baileylicensing.com

Is there an Increase in Valgus Deviation in Tibial Distraction Using ...

WebSynthes Solutions The Expert Tibial Nail PROtect, including its cannulation, is coated with a thin layer (approximately 50 μm) of antibiotic-laden polymer. The coating is abrasion resistant and will withstand most of the forces occurring during nail insertion. The coating releases the antibiotic immediately after implantation for the duration ... Websynthes.hs.llnwd.net WebThe Expert Tibial Nail from Depuy Synthes is a titanium alloy nail which has advanced proximal and distal locking options that assist in the control and stabilisation of difficult … farbton clay

Uncoated vs. Antibiotic-Coated Tibia Nail in Open Diaphyseal …

Category:Lance Sipes posted on LinkedIn

Tags:Synthes expert nail tibia

Synthes expert nail tibia

TN-Advanced Tibial Nailing System - AO …

WebOct 31, 2016 · The Expert Tibial Nail’s use in tibia fracture repair, demonstrates improved patient outcomes, which is why it was selected for application of the PROtect antibiotic coating 7. Web2.7mm/3.5mm VA LCP Medial Distal Tibia, Anteriomedial Distal Tibia, Anterolateral Distal Tibia, Lateral Distal Fibula, and 2.7mm (only) T & L Plates. What is the only sterile boxed plate in the VA Ankle Trauma Set? Anteromedial Name 4 types of screws that can be used with the 2.7 VA locking holes?

Synthes expert nail tibia

Did you know?

http://synthes.vo.llnwd.net/o16/Mobile/Synthes%20International/KYO/Trauma/PDFs/036.000.380.pdf http://www.cambridgeorthopaedics.com/easytrauma/classification/surgtech/ao/manuals/Expert%20Tibial%20Nail%20Surgical%20Technique.pdf

WebExpert Tibial Nail with expandable bio- resorbable sleeves for “enhanced fixation”. Threaded screw holes and polyethylene bushings reduce angular instability. DePuy Synthes® Angular-Stable Locking System (ASLS) Smith & Nephew TRIGEN™ META-NAIL™ Biomet® Phoenix™ Nail System WebThe Tibial Nail Advanced implants are intended for treatment of fractures in adults and adolescents (12-21) in which the growth plates have fused. Specifically, the implants are …

WebCurrently available tibial nails have locking screw holes close to both ends, in multiple orientations, for better fixation of proximal and distal fractures. The nails may be either solid or cannulated (hollow). Solid nails may protect somewhat against infection because they have no internal dead space. WebSynthes Solutions The Expert Tibial Nail PROtect, includ-ing its cannulation, is coated with a thin layer (approximately 50 μm) of antibiotic-laden polymer. 4 Synthes Expert Tibial Nail PROtect PROtect impedes bacteria from adher-ing to the implant surface and produc-ing biofilms. It releases high doses of antibiotics where systemic admission

WebOct 31, 2016 · The Expert Tibial Nail’s use in tibia fracture repair, demonstrates improved patient outcomes, which is why it was selected for application of the PROtect antibiotic coating 7. The design of Expert Tibial Nail itself has been shown to reduce operating time, hospital stay, full weight bearing time and union time 8.

WebA complete transverse tibial osteotomy was performed using a multiple drill hole technique followed by insertion of a conventional tibial interlocking nail (EXPERT TM Tibial Nail; … corporate office party gamesWebMar 1, 2013 · nail insertion, diastasis, compression of the fracture gap. can be accomplished without removing the insertion instruments. The Expert Tibial Nail allows for a maximum … farbton curry 90WebExpert Tibial Nail Surgical Technique - Cambridge Orthopaedics corporate office phone number for amazonWebSo far, surgeons have used the cannulated Expert Tibial Nail which has been provided in two different nail design versions: (1) nail with 10.5° bend starting at 75 mm proximally with a radius of 376 mm to 1128 mm depending on the nail length; (2) nail with 10.5° bend starting at 65 mm proximally with a fixed radius of 100 mm and a 3° tip bend … farbton coyoteWebExpert Tibial Nail (ETN) available with PROtect Coating The Expert Tibial Nail (ETN) is standard in treating tibial fractures with a wide range of indications. The Expert Tibial Nail with PROtect Coating releases high concentrations of antibiotics into the implant’s surroundings to protect your patients from bacterial colonization of the implant. corporate office on sahara in las vegasWebDevice report from synthes europe reports an event in finland as follows: patient implanted with an expert tibial nail protect on (b) (6) 2013. Patient experienced post op breakage while walking with the nail. Patient underwent revision surgery with renailing using a 9mm diameter 360mm etn protect nail. This is report 1 of 1 for complaint (b) (4). farbton db 703 in ralhttp://synthes.vo.llnwd.net/o16/Mobile/Synthes%20International/KYO/Trauma/PDFs/036.000.380.pdf corporate office phone number for at\u0026t